Raymarine
Raymarine ACU-400 Actuator Control Unit E70100
- SKU:
- RAYE70100
- UPC:
- 723193768921
- MPN:
- E70100
- Condition:
- New
Description
Raymarine Evolution ACU Specifications
View AllClose
Model | ACU-100 | ACU-200 | ACU-300 | ACU-400 |
E70098 | E70099 | E70139 | E70100 | |
| ||||
Drive Current Output | Maximum continuous 7 A at supply voltage | Maximum continuous 15 A at supply voltage | Maximum continuous 5 A at supply voltage | Maximum continuous 30 A at supply voltage |
Drive Clutch Output | No clutch connection | Up to 2.0 A continuous, selectable between 12 /24 V | No clutch connection |
|
Connections |
|
|
|
|
Nominal supply voltage | 12 V | 12 V or 24 V | ||
Operating voltage range | 10.8 V to 15.6 V dc | 10.8 V to 31.2 V dc | ||
Power consumption (standby) - main power supply | 300 mA (12V) | 300 mA (12/24 V) | ||
Power consumption (standby) - SeaTalkng power supply | No power supply to SeaTalkng&nbs p; | 20 mA (12V) | ||
SeaTalkng LEN (Load Equivalency Number) | 1 | |||
SeaTalkng Power out | No power supply to SeaTalkng | 3 A at 12 V (fuse protected at 3 A) | ||
Data connections | SeaTalkng | |||
Installation environment | Operating temperature: -20°C to +55°C (-4°F to +131°F) Storage temperature: -30°C to +70°C (-22°F to +158°F) Relative humidity: max 93% | |||
Waterproof rating | Connector panel: IPX2 Drive electronics: IPX6 | Drip resistant | ||
Dimensions (W x H x D) | 180 mm x 140 mm x 52 mm (7.1 in x 5.5 in x 2.0 in) | 285 mm x 211.5 mm x 64.5 mm (11.2 in x 8.3 in x 2.5 in) | ||
Weight | 0.6 kg (1.32 lbs) | 2.2kg (4.84 lbs) | ||
Conformance | Europe: 2004/108/EC Australia and New Zealand: C-Tick, Compliance Level 2 |